106
9. Gate Way10.11.0.1
10. PressSave/Recallbutton and singlebutton
11. name the correlated model upgrade program as Upgrade.adsand
add Tftpd32application program to the catalogue.
12. open IE browserinput the address10.11.0.116press ENTER
13. when the web displaying as following picture,press”apply” button to
upgrate.
2.13-14
2.13.7 Pass/Fail
The Pass/Fail function can monitor changes of signals and output pass or fail signals by
judging the input signal is within the predefined mask or not.
Table 2-56 Pass/Fail function menu 1:
Option Setting Instruction
Enable On
Off
Turn on Pass/Fail function.
Turn off Pass/Fail function.
Source CH1
CH2
CH3
CH4
Slect signal input channel.
Operate
Press to run the Pass/Fail test.
Press to stop the Pass/Fail test.
Msg Display
On
Off
Turn on times information display of the
waveform pass/fail.
Turn off times information display of the
waveform pass/fail.
Next Page Page 1/2
Press this button to enter second page of
Pass/Fail menu.